RAID Recovery™
Recovers all types of corrupted RAID arrays
Recovers all types of corrupted RAID arrays
Last updated: Dec 17, 2025

Best practices for deploying RAID over NVMe-oF — Backup and disaster recovery for NVMe-oF RAID systems

RAID over NVMe-oF (Non-Volatile Memory Express over Fabrics) is reshaping data storage by offering unprecedented speed and reliability. This article explores key strategies for tuning, monitoring, and disaster recovery to maximize performance and safeguard data in RAID over NVMe-oF environments, providing essential guidance for IT professionals.

Executive Summary

  • When deploying RAID over NVMe-oF, it is critical to strategically manage failure domains, ensuring that RAID functionalities are situated where you can control outcomes. This involves exposing multipath configurations to clients to enhance data accessibility and redundancy.
  • Pairing fast local redundancy methods, such as mirrors or local parity, with cluster-grade erasure coding is essential. This combination supports cross-node durability, effectively balancing high-speed data performance with robust protection against data loss.
  • Testing rebuild processes under realistic fabric loads can help ensure system reliability and performance during critical operations. This proactive approach mitigates potential disruptions and verifies the system's capacity to handle real-world challenges.
  • Incorporating disaster recovery (DR) measures from the outset is crucial. DR should be an integral part of the design, rather than an afterthought or an over-reliance on RAID as a sole backup solution. This comprehensive strategy ensures that data systems remain resilient against unexpected failures, providing a safety net that RAID alone cannot guarantee.

Why NVMe-oF Changes RAID Design — Problem Statement

The introduction of NVMe-oF has fundamentally altered the landscape of RAID design due to its ability to leverage high-speed fabrics in data storage environments. This shift introduces unique challenges that require RAID systems to be aware of and adapt to the intricacies of fabric-based architectures.

Firstly, fabrics introduce new path and node failure modes, necessitating a RAID design that can intelligently manage these failures. The sheer speed of NVMe-oF devices further complicates the situation by amplifying performance expectations while simultaneously exposing vulnerabilities and potential points of failure in the system.

Moreover, NVMe-oF shifts traditional bottlenecks from the storage devices themselves to the compute resources and fabric infrastructure. This means that RAID configurations must now prioritize effective placement strategies, multipath data access, and rebuild processes. RAID systems must be optimized to distribute workloads efficiently across the network, ensuring that the increased speed does not lead to an overload of CPU or fabric resources.

Thus, a fabric-aware RAID design strategy is essential. This includes meticulous planning of data placement across nodes, implementing multipath protocols to ensure data accessibility despite potential path failures, and intelligently throttling rebuild operations to maintain system performance during recovery processes. Without these considerations, the benefits of NVMe-oF's speed and efficiency could be undermined by new systemic bottlenecks and failure modes.

Note: what is a RAID hard drive

Best Practices for Deploying RAID over NVMe-oF

1. Choose RAID Layer Intentionally

Selecting the appropriate RAID layer is critical for tailoring system performance and reliability:

  • Host-side RAID: This configuration is ideal for applications requiring ultra-low latency and precise control over storage operations. By situating RAID functionality on the host side, organizations can reduce latency by eliminating additional network hops, and exercise control over single-tenant systems, ensuring performance is dedicated and consistent.
  • Target-side RAID: This setup centralizes RAID operations on storage targets, often utilizing specialized hardware or accelerators to offload processing from the host. This is advantageous for environments where centralized management and enhanced rebuild speeds are priorities, leveraging technology that can accelerate data recovery and consolidation processes.
  • Software-Defined Storage (SDS) Layer: This approach allows for flexible, policy-driven storage management. By implementing RAID at the SDS layer, organizations can enforce policy-based data placement strategies, using erasure coding to enhance data durability across multi-rack or multi-region setups. This is particularly beneficial in cloud or distributed environments where scalability and adaptability are key.

2. Define Failure Domains and Place Members Across Them

Understanding and delineating failure domains is crucial for maximizing system resilience. By distributing RAID members across different chassis, racks, and fabrics, you can prevent large-scale data loss from localized hardware failures:

  • Mapping Mirrors/Stripes: Ensure that data mirrors and stripes are spread across multiple physical locations within the data center. This distribution minimizes the impact of any single component failure, such as a rack or a network segment, thereby improving overall availability and reliability.

3. Expose and Configure Multipathing

Effective multipath configurations enhance data path robustness, ensuring continuity and reliability:

  • NVMe Multipath: Implement NVMe-specific multipath technology to provide multiple paths for data access, thereby increasing redundancy and resilience. This setup facilitates seamless path failover and load balancing across different network connections, ensuring that system throughput remains steady even in the case of path disruptions.
  • Testing Path Failover: Regular testing of path failover scenarios is critical to verifying the system's ability to handle unexpected disconnections or path failures without impacting data accessibility or integrity.

4. Use Hybrid Protection: Local RAID + Cluster EC

Combining local RAID configurations with cluster-level erasure coding offers a balanced protection strategy:

  • Local Mirrors or Dual Parity: Implementing local RAID configurations such as mirrors or dual-parity RAID provides immediate redundancy for frequently accessed (hot) volumes. This ensures rapid recovery in the event of disk failures, maintaining high availability for critical applications.
  • Cluster Erasure Coding: For less frequently accessed (cold) or object storage tiers, utilize erasure coding strategies. This approach optimizes storage efficiency by spreading data and parity across multiple nodes, improving durability and reducing storage overhead while still allowing for data reconstruction in case of failures.

5. Plan for Hot Spares, Spare Pools, and Fast Replacement

A well-thought-out plan for spare management ensures rapid recovery and minimal downtime:

  • Spare Pools: Maintain a pool of hot spare drives that can be automatically allocated to replace failed drives immediately, minimizing the time taken to restore full redundancy.
  • Automated Spare Assignment: Implement automation for spare drive allocation to target nodes. This speeds up the replacement process, ensuring that the system can quickly adapt and continue operations without manual intervention.

Tuning NVMe-oF Fabric RAID for Performance

1. Match Striping & Queue Depth to Fabric Capacity

Optimizing the stripe width alongside the number of NVMe queues and available fabric bandwidth is essential for maximizing throughput and efficiency:

  • Stripe Width: Carefully balance stripe width to match the bandwidth of the fabric. Oversizing stripes relative to the fabric can lead to inefficient use of resources, while undersizing may not fully utilize the available bandwidth.
  • Queue Depth: Align the NVMe queue depth with fabric capacity to ensure consistent data flow and prevent bottlenecks. This practice minimizes latency and maximizes the use of available paths and bandwidth without overloading the network.

2. CPU & Core Pinning for RAID Engines

Efficient CPU utilization is critical for optimal RAID performance:

  • Pinning Threads: Assigning RAID worker threads and NVMe I/O processes to specific CPU cores can prevent latency issues stemming from frequent context switching. This practice helps maintain smooth, uninterrupted processing.
  • Avoiding Hot Spots: Disperse workload assignments to prevent any single core from becoming a bottleneck. A balanced workload distribution across multiple cores ensures better performance and avoids processing delays.

3. Fabric Tuning: MTU, RDMA Credits, QoS

Fine-tuning network parameters is crucial for minimizing delays and enhancing data flow:

  • MTU (Maximum Transmission Unit): Adjust the MTU size to optimize packet transfer rates. The appropriate MTU size can reduce the number of packets required for a transmission, enhancing network efficiency.
  • RDMA/Transport Credits: Properly configure RDMA credits to ensure that queues are managed effectively, reducing retransmissions and maintaining a smooth data flow.
  • Quality of Service (QoS): Implement QoS policies to prioritize traffic effectively, ensuring that rebuild traffic does not impede ongoing I/O operations, thereby maintaining system performance.

4. Rebuild Priority & IO Throttling

Dynamic rebuild strategies ensure consistent system performance:

  • Adaptive Rebuilds: Configure rebuild processes to adjust dynamically based on system load. When the system is under heavy foreground load, slow down rebuild processes to prioritize current operations; when idle, accelerate rebuilds to recover redundancy more quickly.

5. Use Hardware Offload Where Available

Leveraging specialized hardware can free up system resources for application tasks:

  • Hardware Offload: When supported, offload RAID or NVMe-oF target operations to Data Processing Units (DPUs) or smart NICs. This delegation allows the CPU to focus on running applications, significantly improving overall system efficiency and performance.

Monitoring and Maintaining NVMe-oF RAID Health

1. Essential Metrics to Track

Monitoring these key metrics is crucial to ensure the health and performance of NVMe-oF RAID systems:

  • Device SMART/ECC Counts: Regularly track Self-Monitoring, Analysis, and Reporting Technology (SMART) data and Error-Correcting Code (ECC) counts to detect early signs of device degradation or impending failures.
  • Latency P99/P999: Monitor the 99th and 99.9th percentile latencies to understand the tail latency, which indicates the response times under heavy load conditions and potential bottlenecks.
  • Fabric Utilization (GB/s): Measure the bandwidth utilization across the fabric to evaluate whether the available capacity is being effectively used or is nearing saturation.
  • Path Error Rates: Track the frequency of errors across data paths to identify potential issues or failures in the network infrastructure.
  • Rebuild Throughput (GB/s): Monitor the rebuild throughput to ensure that rebuild operations are completing efficiently and within expected time frames.

2. Alerts & Thresholds

Implementing a robust alerts system can proactively mitigate system issues:

  • Rising ECC and Latency: Set up alerts for increasing ECC counts and percentile latencies, which can indicate deteriorating system health or emerging performance issues.
  • Path Flaps: Configure alerts for frequent path flaps, which may point to stability issues in the networking or hardware components.
  • Excessive Rebuild Durations: Generate alerts if rebuild operations exceed expected durations, which could signal underlying issues that need investigation.

3. Scheduled Maintenance & Scrubbing

Regular maintenance ensures ongoing system reliability:

  • Scrubs and Integrity Checks: Schedule scrubbing operations and background integrity checks during low-load periods to minimize impact on system performance. These processes verify data integrity and detect errors, ensuring accurate placement of data.
  • Checksum Verification: Regularly verify checksums to ensure that data has not been corrupted, and confirm that data distribution across devices remains accurate according to the placement maps.

4. Automation & Telemetry

Leveraging automation and telemetry can enhance diagnostic efficiency:

  • Telemetry Pipelines: Utilize telemetry data pipelines to gather comprehensive system information, enabling faster diagnosis of issues and more informed decision-making.
  • Automated Runbooks: Implement automated runbooks to streamline response processes for common issues, reducing the time to resolution and minimizing downtime.
  • Historical Logging: Maintain detailed logs of rebuild histories and fabric state changes for each event, providing critical insights during troubleshooting and future audits.
Tip: how to recover data from a RAID hard drive

Backup and Disaster Recovery for NVMe-oF RAID Systems

1. Design for Multi-Tier DR — Local, Site, Cloud

Creating a robust disaster recovery (DR) plan involves layering strategies across multiple tiers to ensure a comprehensive recovery capability:

  • Local Snapshots: Implement quick, space-efficient snapshots for local data protection. These allow for rapid recovery of recent changes without needing to access remote or cloud resources.
  • Cross-Site Replication: Deploy cross-site replication to maintain synchronized copies of important data across separate locations, ensuring that data remains available even if one site experiences a failure.
  • Offsite Archival: Archive long-term data to object storage with erasure coding, leveraging the cost efficiency and durability of cloud solutions. This approach balances the immediate accessibility of local snapshots with the resilience of offsite storage.

2. Snapshot & Replication Strategy

Develop a resilient strategy for snapshots and replication to minimize recovery time objectives (RTO) and recovery point objectives (RPO):

  • Instant Snapshots: Use space-efficient, instant snapshots to capture point-in-time states of your data. These allow for quick rollbacks in case of corruption or accidental deletion.
  • Continuous Replication: Implement continuous data replication mechanisms to ensure that your system can achieve minimal RPOs, keeping your disaster recovery setups in near-real-time synchronization with production environments.
  • Independent Snapshot Metadata: Store snapshot metadata independently of the RAID controller to avoid dependency issues that could complicate recovery efforts.

3. Test Full Restore and Failover Regularly

Consistent testing ensures that your DR plan is actionable and effective:

  • Snapshot and Dataset Restoration: Regularly test the restore process from both snapshots and replicated datasets. This practice verifies that recovery processes work as expected and allows you to measure the true recovery time and data consistency.

4. Archive Cold Data with Erasure Coding

Manage and archive cold storage effectively to optimize costs:

  • Cold Tier Management: Migrate less frequently accessed cold data to erasure coding-backed object stores. This reduces storage costs while ensuring data durability, as the erasure coding protects against data loss.

5. Include VM/VMFS Recovery in DR Plans

Virtual environments require specific considerations in disaster recovery plans:

  • VM Recovery Paths: Ensure that your DR plans encompass virtual machine disk and metadata recovery processes.
  • Metadata Damage Contingency: In the case of damaged Virtual Machine File System (VMFS) or Virtual Machine Disk (VMDK) metadata, prioritize non-destructive recovery tools, such as DiskInternals VMFS Recovery™, to scan and recover virtual machine files before attempting repairs that could lead to further data loss.

Operational Runbook — Drills & Playbooks

1. Failure Drill Checklist

Regular failure drills are essential for verifying the resilience and response of your system to various fault scenarios. Your checklist should include:

  • Simulating Device Loss: Test scenarios where individual storage devices become unavailable, and observe how the system manages the loss and begins the rebuild process.
  • Path Loss: Simulate the loss of communication paths between components. Ensure that multipath configurations are correctly rerouting traffic and maintaining system functionality.
  • Target/Node Loss: Emulate entire target or node failures to validate your system’s ability to effectively redistribute workloads and initiate recovery procedures. Monitor the impact on applications and services to ensure continuity.

2. Rebuild Playbook

A structured approach to the rebuild process ensures effective recovery from failure events. The playbook should encompass:

  1. Stepwise Approach:
  • Detect: Utilize monitoring tools to quickly detect anomalies or failures.
  • Isolate: Temporarily isolate the affected components to prevent further issues.
  • Assign Spare: Allocate a hot spare from your pool to replace the failed component.
  • Monitor Rebuild: Continuously watch the progress of the rebuild, ensuring it runs smoothly and completes as expected.
  • Validate Checksums: Once rebuilt, confirm data integrity by verifying checksums and ensuring consistency across newly replicated data.
  • Promote: Once validated, reintegrate the rebuilt component into active duty within the system.

3. Emergency Escalation

In the face of significant issues, like failed rebuilds or widespread errors, immediate escalation procedures should be in place:

  1. Initial Actions:
  • Stop Rebuilds: Halt ongoing rebuild operations to prevent exacerbating any potential data issues.
  • Image Namespaces: Capture current system states to preserve data integrity and simplify troubleshooting.
  • Collect Logs: Gather all available system logs to provide a comprehensive overview of the failure conditions.
  1. Execute Non-Destructive Recovery: Run non-destructive recovery tools to assess and potentially recover valuable data while avoiding further harm.
  2. Vendor/Lab Contact: Reach out to your hardware or software vendor and coordinate with a lab for advanced diagnostics and support. This step ensures that expert assistance is available for complex issues beyond your immediate capabilities.
Note: best free RAID recovery software

Comparison table — protection vs performance tradeoffs

StrategyProtection domainPerformance impactRebuild profileBest for
Local mirrors (RAID1/10)Node / chassisLowFast per-mirror copyLow-latency DBs
Parity RAID (RAID6)Node groupModerateHeavy I/OCapacity with resilience
Erasure coding (k/n)Cross-rack/regionCPU/network costNetwork-heavy reconstructObject stores, long-term DR
Hybrid (mirror + EC)Multi-tierTunableTunableHot/cold tiering

Case Studies & Vendor Signals — Real-World Patterns

High-performance NVMe RAID engines, such as xiRAID, and NVMe-oF implementations have demonstrated impressive IOPS (Input/Output Operations Per Second) when the balance between CPU capabilities and fabric infrastructure is optimized. These case studies and vendor experiences underscore the potential performance gains achievable through specialized configurations and targeted optimizations.

Key Observations:

  • Achieving High IOPS: In environments where the CPU and fabric resources are harmoniously aligned, NVMe RAID engines can deliver exceptional performance metrics. This often results in substantial improvements in throughput and latency, significantly enhancing application responsiveness and overall system efficiency.
  • Specialized Tuning Required: To reach these performance milestones, extensive tuning of system parameters is necessary. This includes adjusting the queue depths, optimizing fabric utilization, and ensuring that pathing configurations are perfectly aligned with the storage infrastructure's demands.
  • Utilizing Offloads: The use of specialized hardware offloads, such as Data Processing Units (DPUs) or smart Network Interface Cards (NICs), is often a critical factor in achieving these high performance levels. These devices offload intensive processing tasks from the CPU, freeing up resources for other application-specific demands.
  • Environmental Measurements: Despite the dramatic numbers presented in vendor case studies, it's crucial to measure the actual performance in your specific environmental context. Variations in hardware configurations, application workloads, and network conditions can all influence the real-world effectiveness of these optimizations.

By applying lessons learned from case studies and paying close attention to vendor signals, organizations can effectively navigate the complexities of NVMe-oF deployments, ensuring that they not only meet but exceed their performance expectations.

Related articles

FREE DOWNLOADVer 6.24, WinBUY NOWFrom $249

Please rate this article.
51 reviews