RAID Recovery™
Recovers all types of corrupted RAID arrays
Recovers all types of corrupted RAID arrays
Last updated: Nov 18, 2025

When a RAID array becomes degraded, immediate action is essential to prevent data loss and restore system integrity. This article provides concise steps for addressing RAID warning alerts and troubleshooting rebuild failures. Equip yourself with practical solutions to efficiently resolve RAID degradation issues and safeguard your data.

Immediate Actions

In the event of a RAID degradation, executing immediate and well-informed steps is vital for preserving data integrity. Here’s a detailed guide on how to proceed:

  1. 1. Stop All Writes to the Array: Cease all operations that involve writing data to the RAID array as this can exacerbate the problem and potentially lead to irreversible data loss. Halting writes is a critical first step to maintain the current state of the disk and prevent further corruption.
  2. 2. Create Full Sector-by-Sector Images of All Member Disks: Use reliable imaging software to make exact copies of each disk in the array. This imaging process captures every sector of the disks, ensuring no data is overlooked. These images are crucial as they allow you to work with copies rather than the original disks, minimizing the risk of additional damage.
  3. 3. Document Disk Order and Controller Details: Carefully record the sequence of disks in the RAID array as well as any relevant controller settings or parameters. This documentation is essential for understanding the original configuration and for reference during any recovery attempts.
  4. 4. Attempt Non-Destructive Recovery: With your images and documentation in hand, proceed with a non-destructive recovery approach. This means using recovery software that analyzes the images and attempts to reconstruct the RAID’s data structure without making any changes to the original disks.
  5. 5. Consult a Professional Data Recovery Lab: If non-destructive recovery methods fail or if the situation is beyond the scope of available tools, it is advisable to seek the expertise of a professional data recovery lab. These specialists have advanced tools and the experience needed to handle complex RAID failures, increasing the chances of a successful recovery.

Quick Checklist

Ensuring a successful recovery from a RAID degradation hinges on a meticulous approach. Here’s a detailed breakdown of the crucial steps you should follow:

✔️ Avoid Unnecessary Reboots or Reinitialization:

  • Rationale: Rebooting a system or reinitializing the array can cause data discrepancies or resets in configurations, which might lead to data loss or corruption. These actions might inadvertently cause the RAID array to enter a more severe state of failure.
  • Action: Assess the situation thoroughly before considering a reboot. If a reboot is deemed absolutely necessary, ensure all critical data is backed up and steps are in place to manage the reboot safely.

✔️ Clone Every Disk Before Rebuild Attempts:

  • Rationale: Cloning involves creating an exact copy of each disk's data, ensuring you have a backup that can be referred to in the worst-case scenario where original data becomes inaccessible.
  • Action: Use trusted disk-imaging software to perform sector-by-sector cloning. Store these images securely and verify their integrity before proceeding with any recovery operation.

✔️ Replace Failed Drives and Allow Safe Rebuilds:

  • Rationale: Identifying and replacing explicitly failed drives can prevent further degradation. Allowing the controller to handle rebuilds where feasible ensures that the RAID operates within its intended framework.
  • Action: Once a failed drive is confirmed, replace it with an identical drive if possible. Ensure the RAID controller is configured to automatically engage in rebuilding efforts under safe conditions to restore the array's redundancy.

✔️ Cease Operations if Rebuilds Fail Repeatedly:

  • Rationale: Persistent rebuild failures can indicate deeper issues within the array which could worsen if further unsupervised attempts are made.
  • Action: If you encounter repeated failures during rebuild attempts, discontinue any manual interventions. Instead, utilize dedicated recovery software designed for RAID arrays, or better yet, engage with professional data recovery services. These services can offer in-depth diagnostics and recovery solutions to salvage data efficiently.

Emergency quick table — actions by RAID level

⚙️ RAID Level🚨 Immediate action🔧 Rebuild advice
RAID 0Stop writes, image drives, recover files from imagesRAID 0 has no redundancy — use software recovery or lab.
RAID 1Replace failed drive, allow rebuild; image first if uncertainMirrors rebuild fast; image if controller acts odd.
RAID 5Image all disks, replace failed drive, monitor for UREs during rebuildUREs risk: consider software reconstruction if rebuild fails.
RAID 6Replace failed drive, rebuild; safer but still image before risky opsDual parity tolerates one more failure; image for safety.

What “Degraded” Means — Symptoms & Consequences

Understanding the implications of a "degraded" RAID array is critical for preventing data loss and restoring system functionality. Let's delve into the detailed symptoms and consequences of a degraded RAID array.

Symptoms

A RAID array enters a degraded state when one or more disks in the array experience issues, impacting the array's overall performance and redundancy features. Here are the detailed symptoms:

☛Array Reports “Degraded” or “Read-Only” Status:

  • System Alerts: The RAID management software or firmware often provides alerts or notifications indicating that the array is in a degraded state. This notification is a direct warning that the redundancy provided by the RAID configuration is compromised.
  • Operation Mode Change: In some cases, the array might switch to a read-only mode to preserve current data and protect against further corruption or errors. This mode restricts any new write operations until the issue is addressed.

☛Performance Drops:

  • Increased Access Time: A degraded array often results in slower data retrieval and increased latency because the RAID system compensates for the missing or malfunctioning disk by recalculating data on-the-fly using parity information.
  • Overall Slowdown: Users may notice slower application performance or data transfer rates, which can impact productivity, especially in enterprise environments where data access speed is critical.

☛SMART or Controller Logs Show Errors:

  • SMART Alerts: The Self-Monitoring, Analysis, and Reporting Technology (SMART) embedded within the drives provides health status and can flag potential drive failures through logged errors such as increased bad sectors, reallocated sector counts, or uncorrectable error rates.
  • Controller Error Logs: RAID controller logs will document specific error codes and messages related to the degradation, which can help in diagnosing the faulty component and understanding the exact cause of the issue.

Immediate Consequence

The degradation of a RAID array results in immediate and potentially severe consequences:

☛Reduced Redundancy:

  • Increased Vulnerability: For RAID configurations like RAID 5, the loss of a single disk removes the system's protection against additional failures. If another disk fails while the array is degraded, it can lead to catastrophic data loss, as RAID 5 relies on parity distributed across the array for data recovery in case of a single drive failure.
  • Data Integrity at Risk: With the system operating in a reduced redundancy state, any further issues or unanticipated failures can make data reconstruction impossible, putting the integrity and availability of data at considerable risk.

First 10 Minutes — Do This Now

In the critical first moments after discovering a RAID degradation, swift and strategic actions are paramount to protect your data. Here’s what you should do:

1️⃣Stop All Writes to the Array:

  • Rationale: Immediate cessation of all write operations is essential to prevent further data corruption or loss. Continuing writes can complicate recovery efforts and potentially overwrite critical data.
  • Action: Adjust permissions and halt any processes that might write to the array. This step helps to maintain the array in its current state for easier recovery.

2️⃣Record Essential Information:

  • Disk Order: Carefully note down the sequence in which the disks are arranged in the RAID setup. This information is crucial for any potential reconstruction efforts.
  • RAID Controller Details: Document the make and model of the RAID controller. This includes noting down any details about the controller's cache and battery status, as these impact the array's ability to manage power failures and data integrity.
  • Firmware Versions: Record the current firmware versions in use. Firmware discrepancies can play a significant role in how RAID functions are managed, and knowing the version helps in searching for known issues or updates.

3️⃣Photograph the Setup:

  • Rack and Cabling: Capture detailed photographs of the server rack, cabling arrangement, and disk slot order. These visual records provide a valuable reference to ensure that everything is returned to its previous state after troubleshooting or physical adjustments.
  • Purpose: These images are an insurance against mixed-up cabling or incorrect slot insertion, which can lead to further complications.

4️⃣Create Sector-Level Images:

  • Utilize Imaging Tools: Use tools like ddddrescue, or proprietary vendor tools to create sector-level images of each member disk. This practice involves making complete and exact copies of the disks at the bit-level.
  • Separate Safe Work from Originals: Working with copies, rather than the original disks, minimizes the risk of accidental data alteration. The original disks remain untouched, ensuring a fallback option if recovery does not proceed as planned.

Diagnose: How to Read the Signs

Accurately diagnosing the root cause of a RAID degradation is crucial for effectively addressing the issue. Here's how to interpret the signs you might encounter:

Check Logs & SMART

💡Inspect Controller Logs:

  • Purpose: Controller logs provide detailed information about errors and events related to the RAID array. Look for specific error messages that indicate what might be going wrong with the RAID.
  • Action: Access the RAID management software or firmware to view logs and take note of recurring error codes or warnings. This information can highlight problematic disks or system behaviors that require attention.

💡Review SMART Attributes:

🎚️Essential Metrics: Focus on SMART attributes such as reallocated sectors, pending sectors, and interface errors, as these are direct indicators of disk health and potential failure.

  • Reallocated Sectors: A high count means the disk has moved data from bad sectors to spare ones, signaling physical damage to the disk surface.
  • Pending Sectors: These are sectors that couldn't be read correctly and are awaiting reassessment.
  • Interface Errors: These indicate communication issues between the disk and the controller, which can cause data corruption or loss.

🛠️Action: Use software tools to pull SMART data from each disk. Pay particular attention to any attributes that have been flagged or are trending negatively over time.

Identify Disk vs Controller Failure

⏱️Test Suspected Disks:

  • Standalone Testing: Remove the disk suspected of failure from the array and test it independently. This involves connecting the disk to a standalone system or test bench to see if it still exhibits the same errors.
  • Use Known-Good Bay/HBA: Insert the suspect disk into a known-good bay or Host Bus Adapter (HBA). If the disk operates normally, it suggests the problem may be with the original bay/controller.

🧰Diagnosing Controller-Only Failures:

  • Signs of Controller Issues: If disks work fine outside the array, focus on the RAID controller. A controller failure may not affect the disk data directly but can interfere with how the RAID array is managed, potentially hiding data behind vendor-specific metadata.
  • Action: Check for firmware updates or known issues with the specific model of your RAID controller. If possible, replace the controller with an identical, functioning unit to test if normal operation resumes.

Fix Paths — Ordered by Risk (Low → High)

Addressing RAID degradation successfully requires a methodical approach tailored to the level of risk and specific failure scenarios. Below are detailed steps for various recovery paths, ordered from low to high risk.

1) Safe Rebuild on Healthy Controller (Low Risk)

Procedure:

  • Disk Replacement: Begin by replacing the failed drive with one of equal or greater capacity. It is crucial that this drive is compatible with the existing array setup.
  • Configuration: Enter the RAID management console, typically provided by the hardware or software vendor, and designate the new drive as a "hot spare." This triggers the automatic rebuild process.
  • Monitoring: Closely monitor the drive's SMART attributes, as well as the RAID controller logs, throughout the process. This monitoring helps detect early signs of failure in the new drive or the RAID controller, allowing you to intervene before problems escalate.

2) Manual Rebuild / Force Add (Medium Risk)

Procedure:

  • Preparation: Prior to making any changes, create sector-level images of the existing disks to safeguard against inadvertent data loss. Double-check the disk order to prevent reconstruction errors.
  • CLI Utilization: For manual rebuilds, employ command-line tools specific to your RAID configuration:
  1. mdadm: For Linux-based software RAID, use mdadm to add the new drive and initiate the re-sync process.
  2. StorCLI or Similar: Use these tools for hardware RAID controllers to manipulate the array without damaging metadata.
  • Precautions: Avoid activating any options that reset or modify metadata structures, as this can lead to irreversible data corruption. Manual intervention assumes a working knowledge of RAID configurations and CLI operations, thereby raising the risk profile.

3) Software/Imagery-Based Reconstruction (Lower Destructive Risk)

Procedure:

  • Tool Selection: Use reputable RAID recovery software such as DiskInternals RAID Recovery™. This tool allows for detailed analysis and reconstruction of the RAID array from images.
  • Data Recovery: This application provides options to reconstruct RAID parameters and preview files, enabling you to recover data without affecting the original media.
  • Benefits: The method minimizes risk by working entirely from disk images. This leaves the original disks unaltered and helps avoid further data degradation during the recovery attempt. Essential for scenarios involving logical, rather than physical, corruption.

4) Lab Escalation (Highest Success for Physical Faults)

✔️When to Escalate:

  • Physical Damage Indicators: If there are clear signs of drive damage, such as clicking noises or a complete inability to access the disks, professional intervention is necessary.
  • Persistent Failures: Multiple concurrent failures that resist all above efforts necessitate expert handling.

✔️Action:

  • Professional Evaluation: Engaging a specialized data recovery lab is essential in these cases. Labs have the cleanroom environments needed for safely opening and working on damaged drives, as well as proprietary tools to recover data from even severely impaired media.
  • Maximizing Recovery Potential: Relying on professional services significantly improves the likelihood of recovering valuable data without further risk of loss, particularly when dealing with compounded failures or head crashes.

Why Rebuilds Fail — Common Causes

Understanding the reasons behind rebuild failures in RAID configurations is crucial for effective troubleshooting. Here are some of the common causes that can disrupt the rebuild process:

📛Bad Sectors Propagated During Rebuild (The “Puncture” Problem)

  • Cause: As the rebuild process begins, any pre-existing bad sectors on the remaining operational disks can lead to serious complications. These bad sectors can result in "punctures," where invalid data is inadvertently propagated across the array.
  • Effect: This often causes checksum failures, which are consistency checks designed to ensure data integrity. The rebuild process may halt if it detects that it cannot verify or correct the data being reconstructed.

💾Incorrect Drive Order, Mismatched Partitions, or Controller Metadata Differences

  • Cause: RAID arrays rely on precise configurations and disk order for successful data reconstruction. If disks are inserted in the wrong order or if there are mismatched partitions due to accidental overwrites or previous configuration changes, the rebuild will fail.
  • Effect: Differences in controller metadata — the data structures that define RAID configuration and layout — can also mislead the rebuild algorithm, leading to failure as the RAID controller cannot properly align and reconstruct the data.

🚫Faulty Controller or Backplane Causing Intermittent Disconnects During Rebuild

  • Cause: Hardware issues such as a failing RAID controller or backplane can result in intermittent drive disconnections. These disconnections disrupt the continuous data flow required for successful rebuilds.
  • Effect: Frequent disconnects cause the rebuild process to repeatedly stop and start, potentially leading to corruption or the inability to complete the rebuild. These hardware faults often require the replacement of the controller or backplane to resolve the issue.

Detailed DiskInternals RAID Recovery Workflow — Step-by-Step

Careful and methodical steps are crucial when attempting to recover data from a degraded RAID array using DiskInternals RAID Recovery™. Follow this step-by-step workflow to maximize your chances of successful data recovery.

Step 1 — Documentation & Imaging

  • Photograph and Log: Begin by photographing the physical setup of the RAID array, including disk order, cabling, and connections. Log all serial numbers and collect relevant logs from the RAID management console. This provides a comprehensive record for reference during recovery.
  • Collect Logs: Identify and document any error codes or messages reported in the RAID controller logs or SMART data for each disk.
  • Disk Imaging: Create sector-level images of all member disks using ddrescue or equivalent vendor imaging tools. Save these images to external storage to avoid any impact on the original data. Images serve as your work base, ensuring the originals remain intact.

Step 2 — Non-Destructive Trials

  • Mount Images in a Safe Environment: Use a dedicated recovery system to mount the disk images. Ensure that the environment is isolated from the main working system to prevent accidental write operations.
  • Attempt Import or Reconstruction: Use non-destructive methods such as read-only mount options to attempt an import or reconstruction of the RAID array. This step aims to explore the feasibility of a recovery without altering the existing data.
  • Use DiskInternals RAID Recovery™: Leverage DiskInternals RAID Recovery™ to auto-detect RAID parameters and preview file lists. This tool's capacity to handle various RAID types makes it a powerful ally in assessing the data recoverable from mounted images.

Step 3 — Controlled Rebuild Attempts

  • Assess Evidence: If diagnostics confirm that only one disk has failed, and images of all disks are secured, proceed with caution.
  • Controlled Rebuild: Utilize the same type of RAID controller for rebuild attempts, or employ mdadm for software RAID arrays. Ensure explicit device mappings are used to avoid errors during the rebuild.
  • Monitor for IO Errors: During the rebuild process, closely monitor the system for any input/output errors, which could indicate underlying issues that need addressing before proceeding further.

Step 4 — Verify & Restore

  • File Verification: Once the rebuild or extraction is complete, perform a thorough verification of the recovered files. Use checksums, if available, to confirm data integrity and accuracy.
  • Copy Recovered Data: Transfer the verified data to a clean, secure storage target. This ensures that the currently recovered data is backed up and safe from any potential subsequent failures.
  • Rebuild Array on Fresh Drives: If necessary, use new drives to reconstruct the RAID array, ensuring the fresh setup functions optimally. This step resets the RAID to a stable state, ready for deployment without lingering issues from previous failures.

When to Stop Rebuilding — Red Flags

Recognizing when to halt the rebuilding process is crucial to prevent further data loss or damage. Here are the critical red flags indicating it's time to stop and consider alternative recovery options:

🧱Rebuild Repeatedly Fails with IO Errors or UREs

  • IO Errors: Persistent Input/Output (IO) errors during the rebuild process suggest underlying issues with the disk or RAID controller. These errors can indicate data corruption or hardware faults, necessitating a reassessment of your approach.
  • Unrecoverable Read Errors (UREs): If UREs occur, it points to sectors that cannot be read successfully. This is a critical situation — if these errors persist, it can halt the entire rebuild process, making further attempts potentially damaging.

💽Multiple Drives Show Rising SMART Pending Sector Counts

  • SMART Alerts: If SMART diagnostics reveal that multiple drives are showing increasing counts of pending sectors (sectors awaiting reassessment due to read failures), it signals deteriorating drive health.
  • Consequence: Continued rebuild attempts under these conditions can lead to compounding errors and possible total data loss, as the chances of further drive failures rise significantly.

🕹️Controller Shows Repeated Disconnects or Backplane Issues

  • Frequent Disconnects: If the RAID controller logs show repeated drive disconnects or the backplane is having issues maintaining stable connections, the rebuild process can be severely compromised.
  • Impact: These hardware issues disrupt the continuity necessary for successful data reconstruction, often leading to an unstable or incomplete rebuild, potentially exacerbating data loss.

💡Next Steps:

  • Stop and Image: Immediately cease any further rebuild attempts and create detailed images of all disks. This preserves the current state and prevents additional degradation.
  • Software-Based Reconstruction: Use specialized software to attempt a logical recovery from the images rather than the physical disks. This method focuses on data extraction rather than physical drive repair.
  • Lab Assistance: If software reconstruction doesn't suffice, seek help from a professional data recovery lab. These labs have the expertise and equipment to tackle complex physical issues and provide the highest chances of data recovery.

Prevention Checklist — Avoid Future Degraded Events

Preventing future RAID degradations involves a proactive approach to maintenance and monitoring. Here’s a comprehensive checklist to help you avert such issues:

1️⃣Maintain Hot Spares

  • Implementation: Always have hot spares configured in your RAID setup. A hot spare is a pre-designated disk that automatically joins the array in the event of a disk failure, facilitating immediate rebuilds without manual intervention.
  • Benefit: This reduces downtime and secures continuous data protection by minimizing the time the array operates in a degraded state.

2️⃣Monitor SMART and Controller Logs

  • Regular Checks: Periodically review SMART data for all disks in the array, focusing on metrics like reallocated sectors, pending sectors, and overall disk health.
  • Controller Logs: Keep an eye on RAID controller logs for warnings or errors that could indicate underlying issues.
  • Quick Response: Early detection allows prompt action to replace failing disks before they impact performance or data integrity.

3️⃣Schedule Regular Scrubs/Patrol Reads

  • Purpose: Regular scrubbing or patrol reads help identify and rectify inconsistencies like bad sectors and parity errors before they evolve into more significant issues.
  • Scheduling: Set up periodic scrubs based on the workload and disk utilization patterns. For heavily used systems, more frequent checks may be necessary.

4️⃣Keep Firmware Up to Date

  • Importance: Ensure that both the RAID controller and individual drives are running the latest firmware versions. Updates often include bug fixes and improvements that enhance stability and performance.
  • Vendor Recommendations: Follow manufacturer guidance for updates, balancing performance enhancements with stability to avoid introducing new bugs.

5️⃣Maintain Verified Backups

  • Backup Strategy: Create and maintain a comprehensive backup strategy that involves regular, automated backups to a secure location not reliant on the RAID array.
  • Verification: Regularly test backup integrity and recovery procedures to ensure data can be restored successfully if needed.
  • Distinction: Remember that RAID provides redundancy, not backup. While RAID can protect against disk failure, it doesn’t prevent data loss due to accidental deletion, corruption, or catastrophic events.

Related articles

FREE DOWNLOADVer 6.24, WinBUY NOWFrom $249

Please rate this article.